Downloads
DOI:
https://doi.org/10.7480/jfde.2020.1.4785Keywords:
Daylighting, Glazing system, Window films, Visual comfort, Scale-modelAbstract
Daylight illuminance levels and their spatial distribution are important design elements to achieve indoor visual comfort conditions and sustainability in buildings during the operation stage. While a proper daylighting scheme increases the efficiency of the building, the excessive use of glazed surfaces can contribute to thermal and visual discomfort, hence increasing the cooling demand and use of artificial lighting. Solar control film (SCF) is a self-adhesive thin film that can be applied on glazing systems of existing buildings for retrofitting purposes to modify thermal and optical properties of the glass substrate. This paper analyses experimentally the impact of single glazing with different SCFs on the indoor illuminance levels and respective distribution on horizontal work plane by comparing the measured absolute values and the useful daylight illuminance metric. Field experiments using a small scale model with the glazing oriented to the south, in Lisbon, were performed for a 6 mm clear glass and four different SCFs applied on the external surface of the glass, under clear sky conditions during summer and winter solstice at 9h00, 12h00, and 15h00. The results show that all SCFs reduced the indoor illuminance, which demonstrate their potential for glazing refurbishment when indoor visual discomfort occurs in buildings.
How to Cite
Published
Issue
Section
License
Copyright (c) 2020 Júlia Oliveira Pereira, Maria Glória Gomes, António Moret Rodrigues, Henriqueta Teixeira, Manuela Almeida
This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Authors or their institutions retain copyright to their publications without restrictions.
References
Aghemo, C., Pellegrino, A., & Lo Verso, V. (2008). The approach to daylighting by scale models and sun and sky simulators: A case study for different shading systems. Building and Environment, 43(5), 917-927. doi: 10.1016/j.buildenv.2007.01.020
Ayoub, M. (2020). A review on light transport algorithms and simulation tools to model daylighting inside buildings. Solar Energy, 198, 623-642. doi:10.1016/j.solener.2020.02.018
Boccia, O. & Zazzini, P. (2015). Daylight in buildings equipped with traditional or innovative sources: A critical analysis on the use of the scale model approach. Energy in Buildings, 86, 376-393. doi:10.1016/j.enbuild.2014.10.003
Cannon-Brookes, S. (1994). A study of the use of scale models in the daylighting design of museums. Proc. CIBSE National Lighting Conference, 238 246. Cambridge, England (1994)
Cannon-Brookes, S. (1997). Simple scale models for daylighting design: analysis of sources of error in illuminance prediction. Lighting Research and Technology, 29, 135 142. doi:10.1177/14771535970290030901
Cruz, M., Pereira, J., Gomes, M. G., & Kong, M. M. (2019). Comparative analysis of the
luminous performance of fenestration with Japanese paper and glazing with a polymeric film in meditation rooms. In M. S. M. Kong, M. R. Monteiro, M. J. P. Neto (Eds.), Intelligence, Creativity and Fantasy (pp.555-561). Londres, Reino Unido: CRC Press. doi:10.1201/9780429297755
Curcija, C., Vidanovic, S., Hart, R., Jonsson, J., & Mitchell, R. (2018). WINDOW Technical Documentation, Lawrence Berkeley National Laboratory
European Committee for Standardisation (CEN) (2014). Light & Lighting – Lighting of Indoor Workplaces. Brussels. EN 12464-1
European Window Film Association (2020). Knowledge about Window Films. Available on: https://iwfa.com/ewfa/en-us/Knowledge (consulted on 10/03/2020)
Gomes, M. G., Rodrigues, A. M., & Bogas, J. A. (2012). Numerical and experimental study of the optical properties of venetian blinds. Journal of Building Physics, 36(1), 7-34. doi:10.1177/1744259112444022
Gomes, M. G., Santos, A. J. & Rodrigues, A. M. (2014). Solar and visible optical properties of glazing systems with venetian blinds: Numerical, experimental and blind control study. Building and Environment, 71, 47-59, doi:10.1016/j.buildenv.2013.09.003
Kesten, D., Fiedler, S., Thumm, F., Löffler, A., & Eicker, U. (2010). Evaluation of daylight performance in scale models and a full-scale mock up office. Oxford University Press: International Journal of Low Carbon Technologies, 5, 158 165. doi:10.1093/ijlct/ctq023
Kim, K S., Boyer, L. L., & Degelman, L. O. (1985). Daylighting analysis through scale model, full scale measurements and computer analysis for Texas A&M University Campus Building. Second Annual Symposium Improving Building Energy Efficiency in Hot and Humid Climates, 16 21
Klepeis, N., Nelson, W., Ott, W., Robinson, J., Tsang, A., Switzer, P., Behar, J., Hern, S. & Engelmann, W. (2001). The National Human Activity Pattern Survey (NHAPS): A resource for assessing exposure to environmental pollutants. Journal of Exposure Analysis and Environmental Epidemiology. 11(3), 231-252. doi:10.1038/sj.jea.7500165
Love, J. A., & Navvab, M. (1991). Daylighting estimation under real skies: A comparison of full scale photometry, model photometry and computer simulation. Illuminating Engineering, 20(1), 140 156
Nabil, A. & Mardaljevic, J. (2005). Useful daylight illuminance: A new paradigm for assessing daylight in buildings. Lighting Research and Technology, 37(1), 41-59
Pereira, J., Gomes, M. G., Rodrigues, A. M., & Almeida, M. (2019).Thermal, luminous and energy performance of solar control films in single-glazed windows: Use of energy performance criteria to support decision making. Energy and buildings, 198, 431–443. doi:10.1016/j.enbuild.2019.06.003
Pereira, J., Teixeira, H., Gomes, M. G., & Rodrigues, A. M. (2019). Assessment of early degradation of glazing systems with damaged solar control films. International Conference on Green Construction. 8-9 April 2019, Cordoba, Spain
Potočnik, J. & Košir, M. (2020). Influence of commercial glazing and wall colours on the resulting non-visual daylight conditions of an office. Building and Environment, 171, doi:10.1016/j.buildenv.2019.106627
Reed, B. H., & Nowak, M. A. (1955). Accuracy of daylight prediction by means of models under an artificial sky. Illuminating Engineering, 50(7), 336 346
Reinhart, C. (2005). A simulation-based review of the ubiquitous window-headheight to daylit zone depth rule-of-thumb. IBPSA 2005 - International Building Performance Simulation Association 2005. August 2005,Montreal, Canada
Reinhart, C. & Fitz, A. (2006). Findings from a survey on the current use of daylight simulations in building design. Energy and Buildings, 38(7), 824-835. doi:10.1016/j.enbuild.2006.03.012
Rodrigues, A. M., Santos, M., Gomes, M. G., & Duarte, R. (2019). Impact of natural ventilation on the thermal and energy performance of buildings in a Mediterranean climate. Buildings, 9(5), 123. doi:10.3390/buildings9050123
Roos, A., Polato, P., van Nijnatten, P. A., Hutchins, M. G., Olive, F., & Anderson, C. (2001). Angular-dependent optical properties of low-e and solar control windows: Simulations versus measurements. Solar Energy, 69, 15-26. doi:10.1016/S0038-092X(01)00019-6
Teixeira, H., Gomes, M. G. Rodrigues, A. M., & Pereira, J. (2020). Thermal and visual comfort, energy use and environmental performance of glazing systems with solar control films. Building and Environment, 168. doi:10.1016/j.buildenv.2019.106474